D-84 Parameter ReferenceAC30 series Variable Speed DriveGraphical KeypadSetup::EnvironmentParameters::Keypad::Graphical KeypadParameter Name No. Path Default Range Units WritableView Level 1141 Parameters::Keypad::Graphical Keypad 1 Same as PNO 945 ALWAYSThe view level may be used as a convenient method to hide menus and parameters not currently required. The view levels are:0. Operator – only the “Control Screen”, “Favourites”, “Setup” and “Monitor” menus are visible.1. Technician – additional menus are visible in the “Setup” and “Monitor” menus2. Engineer – the “Parameters” menu is visible in addition to the above.Startup Page 0982 Setup::EnvironmentParameters::Keypad::Graphical Keypad0 0:DEFAULT1:CONTROL SCREEN2:FAVOURITES3:MONITORALWAYSOn power-up the GKP briefly displays the drive name, rating and software version. After a short timeout the display automaticallychanges to the menu defined here0. Default1. Control Screen2. Favourites3. MonitorWhen Startup Page is set to “Default” the first menu will be:The “Control Screen” menu if the drive is in local sequencing mode, otherwiseThe “Favourites” menu if the Favourites menu is not empty, otherwiseThe “Monitor” menu.Display Timeout 0983 Same as PNO 982 0.000 0.000 to 86400.000 s ALWAYSWhen the GKP is idle, (no keys pressed), for a period longer than the Display Timeout, the display will automatically revert to themenu defined in the Startup Page parameter.Setting the Display Timeout to zero defeats this feature.