D-160 Parameter ReferenceAC30 series Variable Speed DriveSoft MenusParameters::Device Manager::Soft MenusParameter Name No. Path Default Range Units WritableControl Screen Mode 0908 Parameters::Device Manager::SoftMenus1 0:DISABLED1:AUTO2:CUSTOMSTOPPEDDefines the operation of the Control Screen0. DISABLED1. AUTO2. CUSTOMWhen set to DISABLED, the Control Screen menu is hidden.When set to AUTO, the contents of the Control Screen menu depends on the sequencing mode of the drive, (local, remote orcommunications).When set to CUSTOM, the contents of the Control Screen may be defined by writing parameter numbers to the elements of the 1352Control Screen array. Note that the contents of the 1352 Control Screen array are not saved in non-volatile memory, so the valuesneed to be initialised following a power-on reset.Control Screen 1352 Parameters::Device Manager::SoftMenusALWAYSAn array of PNOs that identifies the parameters to be shown in the Control Screen. The contents of this screen are set automatically bythe AC30 firmware when the control mode is changed.Favourites 1188 Parameters::Device Manager::SoftMenusALWAYSAn array of PNOs that identifies the parameters to be shown in the Favourites menuSetup 1311 Parameters::Device Manager::SoftMenusALWAYSAn array of PNOs that identifies the parameters to be shown in the Setup menu