501510 Rev. S Troubleshooting 6-7there is not a loose cartridge in the Handler. If there is a cartridge is in the Handler,and it is properly gripped, this will not cause a problem.6.3.7 Z-Axis JammedThe Handler’s Z-Axis (insertion) is unable to move freely. Check that there are noloose magazines or cartridges in the library. Check that all Tape Drives are properlyseated and their locking levers are fastened. If there is a cartridge is in the Handler,and it is properly gripped, this will not cause a problem.6.3.8 Z-Axis ObstructedThe XClear sensor is indicating that it is unsafe to move the Handler in the Z-Axis(insertion). Check that there are no loose magazines or cartridges in the library.Check that all Tape Drives are properly seated and their locking levers are fastened.If there is a cartridge is in the Handler, and it is properly gripped, this will not causea problem.6.3.9 Handler FaultCheck that there are no loose magazines or cartridges in the library.6.3.10 Left Fan Failed or Right Fan FailedThe fan in the left or right Dual-Redundant Power Supply Module is not turning atfull speed. If the fan is not obstructed (by cable ties, etc.), replace the entire PowerSupply Module. This can be accomplished while the RLS continues to function. SeeSection 7.21. Note that left and right are defined when viewing the RLS from thefront. When addressing the power supplies from the rear of the unit, the left modulewill be on your right. Also note that the two fans run off the shared +24V bus. Bothfans continue to run when one of the two Dual-Redundant Power Supply Modulesfails.6.3.11 Left Supply Fail or Right Supply FailThe left or right Dual-Redundant Power Supply Module has failed. Replace the PowerSupply Module, which can be accomplished while the RLS continues to function. SeeSection 7.21. Note that left and right are defined when viewing the RLS from thefront. When addressing the power supplies from the rear of the unit, the left modulewill be on your right. Also note that the two fans run off the shared +24V bus. Bothfans continue to run when one of the two Dual-Redundant Power Supply Modulesfails.