5-24 The Private Menu 501510 Rev. S• AlarmThis value is ON if the +5V-switching regulator’s output voltage is unaccepta-ble.• VoltageThe +5V-switching regulator’s output voltage.• +12VThis value is ON if the RLS has commanded the Drive Carrier to turn on its+12V switching regulator that supplies power to its Tape Drive.• AlarmThis value is ON if the +12V-switching regulator’s output voltage is unaccepta-ble.• VoltageThe +12V-switching regulator’s output voltage.• Inrush LimiterThe Inrush Limiter must be ON for the +5V and +12V switching regulators tooperate.• AlarmThis value is ON if the Inrush Limiter’s output voltage is unacceptable.• VoltageThe Inrush Limiter’s output voltage.• TerminationThis value is ON if the RLS has commanded the Drive Carrier to energize theSCSI Termination Power signal.• AlarmThis value is ON if SCSI Termination Power voltage is unacceptable.• TemperatureThe temperature inside the Drive Carrier in degrees Celsius.• AlarmThis value is ON if the temperature is unacceptable.5.4.17 The Private\Drive Bay\C?\DIA status screenP•Drivebay•C?••••DIAType: ddddddddddControl: dStatus: dThe Private\DriveBay\C?\DIA status screen displays all of the status for theselected (C?) Drive Interface Adapter (DIA) board. The following data is displayed: