Chapter 10: Storage NetworkingConfiguring Host Access to Storage Networking Drives and PartitionsQuantum Scalar i6000 User’s Guide 38113 Click Next to display the Select the partitions for host accessdialog box. In order for a partition to appear on the list, both thefollowing conditions must apply:• the partition has its control path configured via control pathbridging (meaning, the control path is via an HP LTO-5 or LTO-6drive connected to an Ethernet Expansion blade); and• the control path drive has an SNW license applied to it.14 To add partitions to the host access group, select their check boxesin the Select column.15 For each partition selected, make sure to select either Port 1 or Port2 for processing host medium changer commands (the default isPort 1). Both drive ports are active and have different WWPNs, sothe port you choose must be physically connected to a host orswitch or the host will not see it. The port you choose depends onwhich ports on the control path drive are physically cabled.16 Click Finish to create the new access group.Click OK in the The Host Access was updated successfully dialog box.