TimingHi-Data tapes, Model 381, are read at the rate of 10 KC.Hi-Data tapes, Model 382, are read at the rate of 30 KC.Paper tape is read at the rate of up to 1000 characters per second.The tape station connected to the Tape Adapter or Dual Tape Channel is read at the rate of 33.3 KC if it is aModel 581 Tape Station, or 66.7 KC if it is a Model 582 Tape Station.ExampleInstruction:Operation N A Address B Address6 3 2030 2021Tape on Station #3:• Direction of Tape Motion •HSM before Instruction is Executed:2021 2022 2023 2024 2025 2026 2027 2028 2029 2030— — — — — — — — — —HSM after Instruction is Executed:2021 2022 2023 2024 2025 2026 2027 2028 2029 2030A B C D E F G H I JFinal Register Contents:(A)t - 2020(B), = 2021PRIPRZ is setIX-8