16 | P36E-10 Zero Clearance Direct Vent Gas Fireplace|16installationWALL MOUNT ON / OFF SWITCH AND REMOTE RECEIVER INSTALLATIONREQUIRED FOR ALL INSTALLATIONS - INCLUDING PROFLAME REMOTE CONTROLSJ-BoxReceiverWall PlateSlider SwitchLow Voltage Junction BoxDiagram 110 ft. wire harness with12 pin connectorIMPORTANT INSTALLATION NOTE:The Receiver must be placed inside the supplied (Low Voltage)junction type wall box and installed into the wall only.DO NOT INSTALL WITHIN THE CONFINES OF THE FIREPLACE.Remote Receiver Installation1. Install the low voltage junction box to the framing, at desired location within 10 ft. from fireplace.2. Feed the 12 pin connector through the opening at back of junction box.3. Connect the 12 pin connector to the back of the receiver.4. Install the Receiver in the Low Voltage Junction box.5. Insert the 4 AA type batteries in the battery compartment with the correct polarity.6. Place the slider into the cover plate.7. Put the Receiver switch in the “OFF” position, to allow correct lineup for slider switch.8. Make sure the Receiver and cover plate words “ON” and “UP” are on the same side.9. Align the slider with the switch on the Receiver and couple the switch into the slider.10. Align the screw holes.11. Using the two (2) screws provided secure the cover plate to the Receiver.Proflame Receiver