CHAPTER 7. Ошибка! Используйте вкладку "Главная" для применения 제목 1 к тексту, который должен здесьотображаться.7-12 © SAMSUNG Electronics Co., Ltd.7.1.7 Connecting to a Door Phone and a Door LockConnect a door phone and a door lock to the OfficeServ 7200 by using a Door PhoneInterface Module (DPIM).1) Connect a pair of #24 AWG or #26 AWG cables to the LINE port of DPIM and to P1through P8 of 8DLI/16DLI2, D1 through D8 of 8COMBO2/8COMBO3 and P1through P4 of 4DLM of the OfficeServ 7200.Connecting to the 8DLI and 4DLMFigure 7.13 RJ-45 Port of 8DLI and 4DLMPin No. 1 2 3 4 5 6 7 8Function - - - DLI TIP DLI RING - - -Connecting to the 16DLI2Figure 7.14 RJ-45 Port of 16DLI2Pin No. 1 2 3 4 5 6 7 8Function - - - DLITIPDLIRING- - -Connecting to the 8COMBO2/8COMBO3Figure 7.15 RJ-45 Port of the 8COMBO2/8COMBO3Pin No. 1 2 3 4 5 6 7 8Function - - - DLITIPDLIRING- - -P1~P8(RJ-45)P1~P16 Port(RJ-45)D1~D8 Port