PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications49/798.11.3 CF_POWER CommandCommand “CF_POWER_%1” [CR]%1“ON” ----------------------------- Power ON“OFF” --------------------------- Power OFF* Issuing another command during countdown process forced countdownoperation to be terminated.* Error Code is returned in some projector statuses, which indicates thecommand is impossible to be executed. (See [8.3] for details)* Returning the response “000” [CR] (acceptable) does not always mean that thestatus has already changed to Power ON.Example: When the temperature approaches abnormal status after returning“000” [CR] to the command CF_POWER ON.Therefore, to get the projector status requires using Status Read command.Details Set Power to ON/OFFAcceptable “000” [CR]ResponseUnacceptable “Error Code” [CR]8.11.4 CF_FREEZE CommandCommand “CF_FREEZE_%1” [CR]%1“ON” --------------------------- Set Freeze to ON.“OFF” ------------------------- Set Freeze to OFF.“UP” --------------------------- Switch forward (On→Off→On→---)“DN” --------------------------- Switch backward (On→Off→On→---)* The same operation for “UP” and “DN” as this model has only “ON” / “OFF”.DetailsSet / Cancel Freeze function. (Available only in the normal Power ON status)Receiving FREEZE_ON command when the projector is Freeze enabled, Freezestatus is kept.Acceptable “000” [CR]ResponseUnacceptable “Error Code” [CR]8.11.5 CF_VMUTE CommandCommand “CF_VMUTE_%1” [CR]%1 “ON”------------------ Set Video Mute (Shutter Close)“OFF” ----------------Cancel Video Mute (Shutter Open)Details Set / Cancel Video Mute. (Available only in the normal Power ON status)Acceptable “000” [CR]ResponseUnacceptable “Error Code” [CR]