PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications76/799.11.30 CR_SHUTKEYPROT CommandCommand “CR_SHUTKEYPROT” [CR]Details Get status if Shutter can be controlled by key on the top panelAcceptable “000_%1” [CR]%1 “ON” ------------- Shutter is not controllable by key on the top panel“OFF” ------------ Shutter is controllable by key on the top panelResponseUnacceptable “Error Code” [CR]9.11.31 CR_SHUTH CommandCommand “CR_SHUTH” [CR]Details Get time setting to start the shutter managementAcceptable “000_%1” [CR]%1“005” -------------------- 5 minutes“006” -------------------- 6 minutes:“179” -------------------- 179 minutes“180” -------------------- 180 minutesResponseUnacceptable “Error Code” [CR]9.11.32 CR_DELAYCTRL CommandCommand “CR_DELAYCTRL” [CR]Details Get setting status of Video delay controlAcceptable “000_%1” [CR]%1“OFF”---------- Set Video delay control to OFF“LOW”---------- Set Video delay control to LOW“MID”---------- Set Video delay control to MID“HIGH”---------- Set Video delay control to HIGHResponseUnacceptable ““Error Code” [CR]9.11.33 CR_TESTPAT CommandCommand “CR_TESTPAT” [CR]Details Get setting status of Test patternAcceptable “000_%1” [CR]%1“COLOR” ---------------------- Color bar is displayed“GRAD1” ---------------------- 16step(white→black) is displayed“GRAD2” ---------------------- 16step(white←black) is displayed“GRAD3” ---------------------- 16step(white↓black) is displayed“GRAD4” ---------------------- 16step(white↑black) is displayed“WHITE” ---------------------- All white is displayed“BLACK” ---------------------- All black is displayed“CROSS” --------------------- Cross is displayed“OFF” ---------------------Test pattern display is not displayedResponseUnacceptable “Error Code” [CR]