PLC-XU116 Expand Serial Command Functional Specifications65/729.11.10 CR_REAR CommandCommand “CR_REAR” [CR]Details Get setting status of RearResponseAcceptable “000_%1”[CR]%1 “ON” ------------------------------ Rear is ON“OFF” ----------------------------- Rear is OFFUnacceptable “Error Code” [CR]9.11.11 CR_POINTER CommandCommand “CR_POINTER” [CR]Details Get Pointer setting statusResponseAcceptable “000_%a”[CR]%a“SPOTLIGHTMAX” ------- Spotlight Maximum mode“SPOTLIGHTMID” ------- Spotlight Medium mode“SPOTLIGHTMIN” ------- Spotlight Minimum mode“ARROW” ------------------- Arrow Mode“FINGER” ------------------- Finger Mark Mode“LASER” -------------------- Laser Mark ModeUnacceptable “Error Code” [CR]9.11.12 CR_P-MANE CommandCommand “CR_P-MANE”[CR]Details Get Power management setting statusResponseAcceptable “000_%a”[CR]%a“OFF” -------------------------- Power Management is OFF“READY” ---------------------- Power Management is Ready“SHUTDOWN” ---- Power Management is set to Shut Down modeUnacceptable “Error Code” [CR]9.11.13 CR_P-MANETIME CommandCommand “CR_P-MANETIME”[CR]Details Get time to start Power ManagementResponseAcceptable “000_%a”[CR]%a “001”~”030” -----------------------1 minute to 30 minutesUnacceptable “Error Code” [CR]9.11.14 CR_ON-STA CommandCommand “CR_ON-STA”[CR]Details Get Power ON Start setting statusResponseAcceptable “000_%a”[CR]%a “ON” -------------------------- Power ON Start is ON“OFF” ------------------------ Power ON Start is OFFUnacceptable “Error Code” [CR]