PLC-XU116 Expand Serial Command Functional Specifications67/729.11.20 CR_KEYDIS CommandCommand “CR_KEYDIS”(CR)Details Get disablility status of RC/Projector keys (valid or invalid)ResponseAcceptable “000_%a”[CR]%a“NONE” -------------------------- RC / Projector keys are valid“RC” ------------------------------ RC keys are invalid“KEY” ----------------------------- Projector keys are invalidUnacceptable “Error Code” [CR]9.11.21 CR_PJLOCKNOW CommandCommand “CR_PJLOCKNOW” [CR]Details Get if PJ lock is actually in operationResponseAcceptable “000_%1[CR]%1“LOCK” ------------- PJ Lock is in operation. PJ Lock status is ON-1or ON-2 on Menu, and PJ PIN CODE is notentered so that projector is actually locked.“FREE” ------------- PJ Lock is released. PJ Lock status is OFF, or,status is ON-1 or ON-2 on Menu but PJ PINCODE is entered correctly so that PJ Lock isreleased.Unacceptable “Error Code” [CR]9.11.22 CR_PJLOCKMENU CommandCommand “CR_PJLOCKMENU” [CR]Details Get status of PJ Lock on MenuResponseAcceptable “000_%1[CR]%1“ON1” ------------- PJ Lock status is On-1“ON2” ------------- PJ Lock status is On-2“OFF” ------------- PJ Lock status is OFFUnacceptable “Error Code” [CR]9.11.23 CR_FANMODE CommandCommand “CR_FANMODE”[CR]Details Get selected Fan modeResponseAcceptable “000_%a”[CR]%a “L1” ----------------------- Fan mode is L1“L2” ----------------------- Fan mode is L2Unacceptable “Error Code” [CR]9.11.24 CR_FANCONTROL CommandCommand “CR_FANCONTROL”[CR]Details Get selected Fan control setting statusResponseAcceptable “000_%a”[CR]%a“OFF” ----------------------- Fan control is OFF“ON1” ----------------------- Fan control is ON1“ON2” ----------------------- Fan control is ON2“ON3” ----------------------- Fan control is ON3Unacceptable “Error Code” [CR]