– 22 –3-7. Adjust Specifications1. Lens AdjustmentPreparation:POWER switch: ONIf using a ready-made collimator, set to infinity.Note:Do not vibrate during the adjustment.Adjustment method:1. Set the camera 0 cm from the collimator. (Do not enter anylight.)2. Set the camera so that it becomes center of the screen inthe collimator.3. Double-click on the DscCalDi.exe.4. Click the Focus, and click the Yes.5. Lens adjustment value will appear on the screen.6. Click the OK.Adjustment value determination is effectuated using the "STDAFPOS", "FOCUS" and “LENS_ERR” values.If FOCUS=focus1, focus2, focus3, focus4 and the adjustmentvalues fulfill the conditions below, they are determined as withinspecifications.Adjustment value determination1800<=STD_AFPOS<=2000-100<=focus1<=+100, -100-100<=focus3<=+100, -200<=focus4<=+200lens_error=0CameraCollimator3-6. The adjustment item which in necessary in part exchangeCOMPL PWB CP-1LensAdjustmentAWBAdjustmentCCD White PointDefect DetectAdjustmentCCD Black PointAnd White PointDefect DetectAdjustment InLightedFactoryCordSettingUSB storageinformationregistrationLanguageSettingCOMPL PWB ST-1COMPL PWB VF-1ResetSetting: Be sure to carry out the necessary adjustments after replacing the unit.: Adjustment is possible from the menu setting screen of the camera and by using the calibration software.LENS ASSYASSY FLEXIBLE PWB CA1COMPL PWB PW-1DscCalDi xOKFocus ResultSTD_AFPOS=1896FOCUS=-6,1,-7,73ADJ_PZPOS=9LENS_ERR=0!