Section 3 • Scheduled Maintenance ProceduresPart No. 102916 S-100 • S-105 • S-120 • S-125 3 - 23January 2016B-5Perform Hydraulic Oil AnalysisGenie requires that this procedure be performedevery 250 hours or quarterly, whichever comesfirst.Replacement or testing of the hydraulic oil isessential for good machine performance andservice life. Dirty oil and a clogged suction straineror hydraulic filters may cause the machine toperform poorly and continued use may causecomponent damage. Extremely dirty conditionsmay require oil changes to be performed moreoften.Note: Before replacing the hydraulic oil, the oil maybe tested by an oil distributor for specific levelsof contamination to verify that changing the oil isnecessary. If the hydraulic oil is not replaced atthe two year inspection, test the oil quarterly.Replace the oil when it fails the test.See E-1, Test or Replace the Hydraulic Oil.B-6Perform Engine Maintenance -Deutz ModelsEngine specifications require that this procedurebe performed every 250 hours.Proper engine maintenance, following the enginemanufacturer's maintenance schedule, is essentialto good engine performance and service life.Failure to perform the maintenance procedurescan lead to poor engine performance andcomponent damage.Required maintenance procedures and additionalengine information are available in theDeutz F4L913 Operation Manual(Deutz part number 0297-7341) OR theDeutz BF4L2011 Operation Manual(Deutz part number 0297-9929) OR theDeutz TD 2.9 Operation Manual(Deutz part number 0312-3893) OR theDeutz TD 2011 Operation Manual(Deutz part number 0312-3547).Deutz F4L913 Operation ManualGenie part number 62446Deutz BF4L2011 Operation ManualGenie part number 84794Deutz TD 2.9 Operation ManualGenie part number 1251561Deutz TD 2011 Operation ManualGenie part number 139320CHECKLIST B PROCEDURES