www.Wayne-Dalton.com 349981 REV2_05/17/2016©Copyright 2016 Wayne Dalton, a division of Overhead Door Corporation50TROUBLE POTENTIAL CAUSE NOTES / CORRECTIVE ACTIONDoor limits have shifted Position Sensor fault/failure1. Verify Position Sensor connections.2. Verify magnet in position sensor has not moved and has not rubbed againstthe encoder.3. Reset limits.CONTROL PANEL TROUBLESHOOTING (CONTINUED)OPENSTOPCLOSE+24VFig 7–JMESSAGE DISPLAYED CAUSE NOTES / CORRECTIVE ACTION- - - - - - - - - - - - - Displayed if no message code is present in the Event or Error Log. Contact service representative.STATUSIdle Door at rest, not at open, close, mid limits. Displayed when door is motionless in Idle and not at open, close, open P1 limits.Door stopped using the STOP key.STATUSCount down Door at rest and counting down to timed close or open. Time remaining in seconds is displayed.STATUS -OPENINGOpening Door opening. Displayed while door is opening from activation.STATUS - CLOSINGClosing Door closing. Displayed while door is closing from activation.STATUS -STOPStop Door stopping. Displayed while door is stopping from activation.STATUSLocked Incorrect pass code input. Displayed when the wrong pass code is enteredClosed Position at close limit.Open Position at open limit.Open P1 Position at 75% of open limit.Open P2 Position at mid limit.CONTROL PANEL STATUS MESSAGES