3-26 Phaser 6121MFP Service ManualError Messages and CodesTransmission ErrorsThe transmission error before “Phase-B” performs redial according to the redialinterval of each country and the number of times.The transmission error after “Phase-C” performs redial only one time. Transmissionis canceled when an error occurs again.For information on the acronyms in the illustration above, see “Common FaxTransfer Commands” on page 4-11.Code Possible Causes of Error0080 Cannot detect a G3 signal within 35 seconds specified by ITU-T inphase B.0081 Received DTC signal in transmission phase.0082 Transmitting unit receives a signal other than DIS or DTC and DCN inphase B.0083 Detected FSK signal, but did not receive any signal within 35 seconds.0084 Detect DCN signal in phase B.0085 Transmitting unit sending DCS 3 times consecutively, but each timeresponds with DIS/DTC.0086 Detected responds signal other than DTC, DIS, FTT, DCN or CFR aftersending DCS.0087 Training attempt has failed because speed of the unit can not adjustto lower speed.0088 Received DCN signal after sending out DCS signal.008B Receiver’s protocol of DIS is received, but it is not compatible with thismachine.s6121mfp-374CNGCEDDIS (CSI)TCF (TSI) DCSCFRAt EOM TXAt MPS TXPIX DATAEOP or (MPS)or (EOM)MCFDCNAt EOM RXAt MPS RXABCDE