APPLICATIONS OF Σ-SERIES PRODUCTS3.7.5 Using Running Output Signal132Example: When preset value is 100 and reference speed is 2000 r/min.V-CMP is ON (circuit between 1CN-8 and 1CN-10 is closed) when the speed is between1,900 and 2,100 r/min.3.7.5 Using Running Output Signal1) This section describes how to wire and use contact output signal TGON as a running out-put signal. This signal indicates that a servomotor is currently running.Photocoupler OutputPer output:Maximum operationvoltage: 30 VDCMaximum outputcurrent: 50 mADCServopackI/O powersupplyOutput → TGON 1CN-9 Running Output (Torque LimitOutput)For Speed/TorqueControl andPosition ControlThis output signal indicates that the motor is cur-rently running.It is used as an external interlock.ONstatus:Circuit between 1CN-9 and 1CN-10 isclosed.1CN-9 is at low level.Motor is running.(Motor speed is greater than the presetvalue.)OFFstatus:Circuit between 1CN-9 and 1CN-10 isopen.1CN-9 is at high level.Motor is stopped.(Motor speed is below the preset value.)Preset value: Cn-0B (zero-speed level)Note This function is changed to another function depending on the setting of bit 4 ofmemory switch Cn-01.3Motorspeed