APPLICATIONS OF Σ-SERIES PRODUCTS3.8.2 Wiring for Noise Control138MCCB or Fuse for Each Power CapacityPowerVoltage Servopack TypePower Capacity PerServopack (kVA)(see note 1)Power Capacity PerMCCB or Fuse (A)(see note 2)SGDA-A3Aj 0.25SGDA-A5Aj 0.3 5200 V SGDA-01Aj 0.5 5200 V SGDA-02Aj 0.75SGDA-04Aj 1.2 9SGDA-08Aj 2.2 16SGDA-A3Bj 0.2SGDA-A5Bj 0.3 5100 V SGDA-01Bj 0.55100 VSGDA-02Bj 0.75 8SGDA-03Bj 1.4 15Note 1) Power capacity at rated load2) Operating characteristics (25°C): 2 seconds or more for 200%, 0.01 second or more for700%3) A fast-operating fuse cannot be used because the Servopack power supply is a capaci-tor input type. A fast-operating fuse may blow out when the power is turned ON.3.8.2 Wiring for Noise Control1) Example of Wiring for Noise Controla) This Servopack uses high-speed switching elements in the main circuit. It may re-ceive “switching noise” from these high-speed switching elements if wiring or ground-ing around the Servopack is not appropriate. To prevent this, always wire and groundthe Servopack correctly.b) This Servopack has a built-in microprocessor (CPU). To protect the microprocessorfrom external noise, install a noise filter in place.3