Select Cn-00.The selected digitblinks.USING THE DIGITAL OPERATOR4.2.6 Clearing Alarm Trace-back Data2024.2.6 Clearing Alarm Trace-back Data1) This procedure clears the alarm history, which stores the alarms occurring in the Servo-pack. Each alarm in the alarm history is set to A99, which is not an alarm code. Refer to4.2.1 Operation in Alarm Trace-back Mode for details.2) Follow the procedure below to clear the alarm trace-back data.For JUSP-OP02A-11) Press DSPLSET to select the user constantsetting mode.2) Select the user constant number Cn-00.(User constant Cn-00 is selected when thepower is turned ON.)Press the and keys to select the digit.Press the and keys to change thevalue.3) Press DATAENTER to display the current data forthe user constant Cn-00.4) Press the and keys to change thedata to 02.5) Press DSPLSET to clear the alarm trace-backdata.6) Press DATAENTER to return to the user constantdata display.For JUSP-OP03A1) PressMODE/SETto select the user constantsetting mode.4JUSP-OP02A-1Setting ModeUser Constant Number DataSet to 00-02.keys to change thevalue.Press theClear the alarm trace-back data.User Constant Number DataJUSP-OP03ASetting Mode