2. DIGITAL OPERATOR (JVOP-114) (Cont'd)2 .8 .3 Third Functions (Constant Nos . 32 to 59)Function No. Name Description InitialSettingUserSetValuesRefer-ePage0 . FWD/REV run command (3-wire sequence selection)1 : External fault (NO contactinput)2 : External fault (NC contactinput)Multifunction 3 : Multi-step speed reference 1Input Selection 1 4 Multi-step speed reference 2(Terminal 3 5 : JOG command32 Function 6 : Accel/decel time select 13 116Selection) 7 : External baseblock (NOcontact input)8 : External baseblock (NCcontact input)c 9 : Search command from°- maximum frequency10 : Search command from settingContact frequencyco Input 11 : Accel/decel hold12 : LOCAL/REMOTE selectSignal 13 : Alarm reset1 External fault (NO contactinput)2 : External fault (NC contactinput)3 : Multi-step speed reference 14 - Multi-step speed reference 2Multifunction 5 : JOG command33 Input Selection 2 6 : Accel/decel time select(Terminal 4 7 : External baseblock (NO 1 117Function contact input)Selection) 8 : External baseblock (NCcontact input)9 : Search command frommaximum frequency10- Search command fromsetting frequency11 : Accel/decel hold12 - LOCAL/REMOTE select13 . Alarm reset