2 . DIGITAL OPERATOR (JVOP-114) (Conttd)C.C .-ELY DECEL HOLD COMMANDWhen the accel/decel hold command is input duringacceleration or deceleration, acceleration ordeceleration is prohibited while: the command is input,and the output frequency is held.By inputting the stop command, the accel/decel ;command is released and the operation is in the stoppedcondition .The accel/decel hold command is input frommultifunction contact input terminal 30, ® or 05 .For the function of terminal 3;, RD or (1, set "8" to32 , R or ®.Terminal 30 function : Set to 32 .Terminal U function : Set to 33 .Terminal (3) function : Set to ®.The following shows the time chart when theaccel/decel hold command is inputFWD RUN ONI iACCEL/DECEL - I oN N ONHOLD COMMAND IIFREQUENCY I I~,REFERENCE I I OUTPUT I I IFREQUENCYI I1 -1FREQUENCY AGREED ON oNSIGNAL- 13 7 -Note : When the FWD (REV) run command is input in the status where the accel/decelhold command is input, the baseblock status is continued and the motor does notoperate .However, when frequency reference lower limit 25 ? minimum output frequency Cis set, the motor operates at the frequency reference lower time 25 .Item Name Constant to be Set Factory PresetAccel/Decel Hold Function ~32, 0, i9 See page 90.