“Set” (Menu) ModeThe FT-2980R Set (Menu) mode, already described in parts of many previous chapters, iseasy to activate and set. It may be used for configuration of a wide variety of transceiverparameters, some of which have not been detailed previously. Use the following procedureto activate the Set (Menu) mode:1. Press and hold in the [MHz(SET)] key for one second to enter the Set mode.2. Rotate the DIAL knob to select the Menu Item to be adjusted.3. Press the [MHz(SET)] key momentarily to enable adjustment of the selected Menuitem, then rotate the DIAL knob to perform the actual adjustment.4. After completing your selection and adjustment, press and hold in the [MHz(SET)]key for one second to exit the Set mode and resume normal operation.Menu Item Function Available Values Default1 APO Enables/Disables the Automatic Power Off feature. 30MIN / 1HOUR /3HOUR / 5HOUR /8HOUR / OFFOFF2 AR BEP Selects the Beep option during ARTS™ operation. IN RNG / ALWAYS / OFF IN RNG3 AR INT Selects the Polling Interval during ARTS™ operation. 25SEC / 15SEC 25SEC4 ARS Activates/Deactivates the Automatic Repeater Shiftfeature. ON / OFF ON5 BCLO Enables/Disables the Busy Channel Lock-Out fea-ture. ON / OFF OFF6 BEEP Enables/Disables the key beeper. KY+SCN / KEY / OFF KY+SCN7 BELL Selects the CTCSS/DCS/EPCS Bell Ringer repeti-tions.1 / 3 / 5 / 8 /CNTNUE / OFF OFF8 BNK.LNK Select the Memory Bank for the Memory Bank LinkScan. --- ---9 BNK NM Programming an Alpha/Numeric label for a MemoryBank. --- ---10 CLK.SFT Shifting of the CPU clock frequency. ON / OFF OFF11 CW ID Enables/Disables the CW identifier during ARTS™Operation. ON / OFF OFF12 CWTRNG Enables/Disables the CW Training feature and se-lects the sending speed of the morse Code.4WPM - 13WPM /15WPM / 17WPM /20WPM / 24WPM /30WPM / 40WPM / OFF(20CPM - 65CPM (5CPMmultiples) / 75CPM /85CPM / 100CPM /120CPM / 150CPM /200CPM)OFF13 DC VLT Indicates the DC Supply Voltage. --- ---14 DCS CD Setting of the DCS code. 104 standard DCS codes 02315 DCS RV Enables/Disables “Inverted” DCS code decoding. ENABLE / DISABL DISABL16 DIMMER Setting of the front panel display’s illumination level. LVL 0 (OFF) - LVL 10 LVL 517 DT A/M Enables/Disables the DTMF Autodialer feature. MANUAL / AUTO MANUAL18 DT DLY Setting of the DTMF Autodialer’s TX Delay Time. 50 / 250 / 450 / 750 /1000 (ms) 450 (ms)19 DT SET Loading of the DTMF Autodialer Memories. --- ---61FT-2980R Operating Manual