45FT-7800R OPERATING MANUALS CANNINGPROGRAMMABLE (BAND L IMIT) MEMORY SCAN (PMS)This feature allows you to set sub-band limits for either scanning or manual VFO operation.For example, you might with to set up a limit (in North America) of 144.300 MHz to 148.000MHz so as to prevent encroachment into the SSB/CW “Weak Signal” portion of the bandbelow 144.300 MHz. Here’s how to do this:1. Set the radio to the VFO mode by pressing the [V/M(MW)] key, if necessary.2. Using the techniques learned earlier, store 144.300 MHz into Memory Channel “L1”(the “L” designates the Lower sub-band limit).3. Likewise, store 148.000 MHz into Memory Channel “U1” (the “U” designates the Up-per sub-band limit).4. Switch to the Memory mode by pressing the [V/M(MW)]key once, then rotate the DIAL knob to select MemoryChannel “L1.”5. Press the [BAND(SEL)] key momentarily to start PMSoperation; the “ ” label will appear on the display.Tuning and scanning (engaged by pressing the[SCAN(SEL)] key momentarily) will now be limited within the just-programmed range.6. Fifty pairs of Band Limit memories, labeled L1/U1 through L50/U50, are available.You therefore can set upper and lower operation limits on a number of bands, if you like.