63ScanningSearching for signals● Canceling scanningPress [PTT] on the microphone to cancel scanning (this does not put the transceiverinto transmit mode).Selecting the receiver operation performed after scanning stopsSelect one of the following 3 receiving operations to be performed after the scanningstops.(1) Restart scanning after receiving the frequency for the set amount of time. Selectfrom 1, 3 or 5 seconds.(2) Continue receiving the frequency until the signal disappears, and then restartscanning 2 seconds after the signal disappears (BUSY).(3) Stop scanning and receive that frequency (HOLD).1 Press and hold for over one second.The Setup menu appears.2 Rotate the DIAL to select [5 SCAN], then press.The menu list appears.3 Rotate the DIAL to select [3 SCAN RESUME], thenpress .The options for receiver operation appear.4 Rotate the DIAL to select the desired receiveroperation, then press .“1 BUSY” → “2 HOLD” → “3 1sec” → “4 3sec” → “55sec”Tip The default setting: 1 BUSY5 Press and hold for over one second.The receiver scanning operation is set, and the display returns to the previousoperating screen.TipThe settings here are applied for “VFO Scan”, “Memory Scan” and “Programmable Memory Scan”.