NORDAC START (SK 135E / SK 175E) – Users Manual for Motor Starters68 BU 0135 en-41184.2.3 Commissioning examplesAll SK 1x5E devices can basically be operated in the condition in which they are delivered.If an automatic start-up is required when "Mains on" takes place (depending on setting P130), eitheradapt parameter (P428) or set DIP switch S1-DIP1 = ON.The PTC input must be bypassed, if a motor with PTC is not available.The motor starter must be provided with an external 24 V DC control voltage.Minimal configurationMotor starterSK 1x5E-... X54440..2122.3839L1 - L2 - L3 PE200 … 500V24V=GND3~ 200 … 500V + PESwitch S1Motor PTCMotor start via switchMotor start with direction of rotation "right":• If the switch is set to "On" and 24 V DC is therefore present at digital input 1 (terminal 21), themotor starter starts to operate in the "right" (clockwise) direction.Motor start with direction of rotation "left":• If the switch is set to "On" and 24 V DC is therefore present at digital input 2 (terminal 22), themotor starter starts to operate in the "left" (anticlockwise) direction.Motor start via mains voltage "ON"DIP switch S1 / DIP1 = ON corresponds to automatic startMotor start with direction of rotation "right":• If the mains voltage is set to "On" and 24 V DC is therefore present at digital input 1 (terminal 21),the motor starter automatically starts to operate in the "right" (clockwise) direction.Motor start with direction of rotation "left":• If the mains voltage is set to "On" and 24 V DC is therefore present at digital input 2 (terminal 22),the motor starter automatically starts to operate in the "left" (anticlockwise) direction.