194 Technical dataShock/Drop (ISTA) Not allowed R1 …R4 (ISTA 1A): Drop, 6 faces, 3edges and 1 cornerR5…R9 (ISTA 3E): Shock, inclineimpact: 1.1 m/s (3.61 ft/s)Shock, rotational edge drop: 200 mm(7.9 in)1) For neutral-grounded TN and TT systems and non-corner grounded IT systems.See also section Limiting relay output maximum voltages at high installation altitudes onpage 86.2) For corner-grounded TN, TT and IT systemsMaterialsDrive enclosure • PC/ABS 3 mm, PC+GF10 3mm, color NCS 1502-Y(RAL 9002 / PMS 1C Cool Grey), RAL 9002 and PMS425 C• hot-dip zinc coated steel sheet 1.5 to 2.5 mm, thicknessof coating 100 micrometers, color NCS 1502-YPackage Plywood, cardboard and molded pulp. Foam cushions PE,PP-E, bands PP.Disposal The main parts of the drive can be recycled to preservenatural resources and energy. Product parts and materialsshould be dismantled and separated.Generally all metals, such as steel, aluminum, copper andits alloys, and precious metals can be recycled asmaterial. Plastics, rubber, cardboard and other packagingmaterial can be used in energy recovery. Printed circuitboards and DC capacitors (C1-1 to C1-x) need selectivetreatment according to IEC 62635 guidelines. To aidrecycling, plastic parts are marked with an appropriateidentification code.Contact your local distributor for further information onenvironmental aspects and recycling instructions forprofessional recyclers. End of life treatment must followinternational and local regulations.Applicable standardsThe drive complies with the following standards. The compliance with the European LowVoltage Directive is verified according to standard EN 61800-5-1.Weight range mm in0…10 kg (0…22 lb) 760 29.910…19 kg (22…42 lb) 610 24.019…28 kg (42…62 lb) 460 18.128…41 kg (62…90 lb) 340 13.4