Parameters 319DI6 Digital input DI6 (10.02 DI delayed status, bit 5). 8DIO1 Digital input/output DIO1 (11.02 DIO delayed status, bit 0). 11DIO2 Digital input/output DIO2 (11.02 DIO delayed status, bit 1). 12Other [bit] Source selection (see Terms and abbreviations on page 112). -40.91 Feedback datastorageStorage parameter for receiving a process feedback value eg.through the embedded fieldbus interface.The value can be sent to the drive as Modbus I/O data. Setthe target selection parameter of that particular data(58.101…58.124) to Feedback data storage. In 40.08 Set 1feedback 1 source (or 40.09 Set 1 feedback 2 source), selectFeedback data storage.--327.68 … 327.67 Storage parameter for process feedback. 100 = 140.92 Setpoint datastorageStorage parameter for receiving a process setpoint value eg.through the embedded fieldbus interface.The value can be sent to the drive as Modbus I/O data. Setthe target selection parameter of that particular data(58.101…58.124) to Setpoint data storage. In 40.16 Set 1setpoint 1 source (or 40.17 Set 1 setpoint 2 source), selectSetpoint data storage.--327.68 … 327.67 Storage parameter for process setpoint. 100 = 14141 Process PID set 2 A second set of parameter values for process PID control.The selection between this set and first set (parameter group40 Process PID set 1) is made by parameter 40.57 PIDset1/set2 selection.See also parameters 40.01…40.06, 40.91, 40.92, and thecontrol chain diagrams on pages 590 and 591.41.07 Set 2 PID operationmodeSee parameter 40.07 Set 1 PID operation mode. Off41.08 Set 2 feedback 1sourceSee parameter 40.08 Set 1 feedback 1 source. AI1 scaled41.09 Set 2 feedback 2sourceSee parameter 40.09 Set 1 feedback 2 source. Not selected41.10 Set 2 feedbackfunctionSee parameter 40.10 Set 1 feedback function. In141.11 Set 2 feedback filtertimeSee parameter 40.11 Set 1 feedback filter time. 0.000 s41.12 Set 2 unit selection Defines the unit for parameters 41.21…41.24 and 41.47. %rpm rpm. 7% %. 4Hz Hz. 3PID user unit 2 User-definable unit 2. The name of the unit can be edited onthe control panel by choosing Menu – Settings – Edit texts.24941.14 Set 2 setpointscalingSee parameter 40.14 Set 1 setpoint scaling. 100.0041.15 Set 2 output scaling See parameter 40.15 Set 1 output scaling. 1500.00;1800.00(95.20 b0)41.16 Set 2 setpoint 1sourceSee parameter 40.16 Set 1 setpoint 1 source. InternalsetpointNo. Name/Value Description Def/FbEq16ghv Vertriebs-GmbH | Am Schammacher Feld 47 | 85567 Grafing | Telefon + 49 80 92 81 89 0 | info@ghv.de | www.ghv.de