Operation and Maintenance195Aastra 415/430 as of R3.2syd-0344/1.6 – R3.2 – 09.20146. 3. 3. 3 New card with more portsA card is replaced by a similar card with more ports.Procedure:1. Change the card and put the system into operation again. Similar procedure asdescribed in "Replacing a defective interface card", page 193.2. In the WebAdmin view Cards and modules ( =4g) Confirm the new cards.3. Configure new ports.The system configuration data (User No., User configuration, etc.) of the terminalson the new ports is created as new data (default values).Tab. 83 Example: Expanding the number of terminal or network interfaces6. 3. 3. 4 Change slotInterface cards can be moved to a different slot. The terminal configuration data ofthe system phones can be transferred.Procedure:1. Change the slot and put the system into operation again. Similar procedure asdescribed in "Replacing a defective interface card", page 193.Note:The wiring adapter must also be changed to the corresponding slot.Any incorrectly fitted or missing wiring adapters are signalled by a redflashing LED on the display after start-up (see "Wiring Adapter Mal-function Mode", page 209).2. Connect the system terminals to the ports of the new slot.3. Reconfigure the port assignment.4. In the WebAdmin view Cards and modules ( =4g) Confirm card in the new slotand Delete it from the old slot. The configuration data at the old slot location isnow deleted.Note:Not all cards can be equipped on all slots (see "Component mountingrules", page 100).TIC-2TS TIC-4TS The configuration data of terminal interfaces 3 and 4 are created as new.TIC-2AB TIC-4AB The configuration data of network interfaces 3 and 4 are created as new.