TCP/IP27Logical Printer SetupPhysical Port(0100 L1_PROUT)Print Server Port to which the printer is attached(P1 to P3 for parallel ports and SP for the serialport).String Before Job(0101 L1_PREST)The printer control string (in hex) to be sent tothe printer before each print job.String After Job(0102 L1_POSTR)The printer control string (in hex) to be sent tothe printer after each print job.Convert LF to CR+LF(0103 L1_CHGLF)If ON, LF (line feed) characters are changed toCR+LF (carriage return + line feed). If OFF, noconversion is done.The maximum size of a printer control string is 15 characters.Logical PrintersPrint Server models with 1 parallel port support 3 Logical Printers, otherwise theysupport 8 Logical Printers. The names (L1..L8) cannot be changed. Each LogicalPrinter has 4 settings as shown above. The line numbers in the Print Server’sCONFIG file are as follows:Logical Printer Line NumbersL1 0100 to 0103L2 0120 to 0123L3 0140 to 0143L4 0160 to 0163L5 0180 to 0183L6 0200 to 0203L7 0220 to 0223L8 0240 to 0243