Snap Server 700i Series User’s Guide 101Chapter 9Maintaining Your iSCSI StorageApplianceThis chapter describes how to use Adaptec Storage Manager to configure the UPSmonitor, blink devices, shut down and restart your iSCSI Storage Appliance,change the appliance settings, and update the Adaptec OnTarget operating system.For more information about your iSCSI Storage Appliance, see “Your Snap Server700i Series” on page 187.Note To add and configure a new iSCSI Storage Appliance after initial IP SANsetup is complete, see “Adding an iSCSI Storage Appliance” on page 86.Configuring the Uninterruptible Power Supply (UPS)MonitorYou can use Adaptec Storage Manager to set the UPS monitor settings for eachiSCSI Storage Appliance in your IP SAN. You can set customized UPS monitorsettings for each separate iSCSI Storage Appliance.You can monitor the UPS using either a USB or SNMP connection.Note If the UPS broadcasts that it’s about to shut down, your iSCSI StorageAppliance will also shut down if it is connected to the UPS through an SNMPconnection.To configure UPS monitor settings:1 In the Enterprise view, select the iSCSI Storage Appliance.2 In the Actions menu, select Configure UPS monitor.The Uninterruptible Power Supply (UPS) Configuration window opens.