Rebuilding PoolsChapter 12 Solving Problems 147Removing a Failed Disk Drive’s Icon from Adaptec Storage ManagerNote You can only complete this task on disk drives that are not included in anypool.When a disk drive fails, it may still appear in Adaptec Storage Manager although itis no longer available. To see an accurate representation of your IP SAN and make iteasier to monitor your disk drives, you can remove a failed disk drive from thePhysical Devices View.In the Physical Devices View, right-click the failed disk drive, then select Removefailed drive.Rebuilding PoolsA hot-swap rebuild occurs when a controller detects that a failed disk drive in a poolhas been removed and then reinserted.To start a hot-swap rebuild:1 Following the instructions in “Hot Swapping Disk Drives” on page 144, gentlypull the failed disk drive from the server without fully removing it, then wait forit to spin down fully before continuing.2 If nothing is wrong with the disk drive, reinstall it.If necessary, replace the failed disk drive with a new disk drive of equal or largersize.3 The controller detects the reinserted (or new) disk drive and begins to rebuild the pool.