AXIS P1353–E Network CameraSystem Options1. Disconnect power from the product.2. Press and hold the control button and reconnect power. See Hardware Overview, on page 6 .3. Keep the control button pressed for about 15–30 seconds until the status LED indicator flashes amber.4. Release the control button. The process is complete when the status LED indicator turns green. The product has been resetto the factory default settings. If no DHCP server is available on the network, the default IP address is 192.168.0.905. Use the tools provided on the Installation and Management Software CD to assign an IP address, set the password andaccess the video stream. This information is also available from the support pages on www.axis.com/techsup6. Refocus the product.It is also possible to reset parameters to factory default via the web interface. Go to Setup > System Options > Maintenance.55