Chapter 3: LM Security Screens for 2H23-50R/2H33-37R Devices3-6Local Management Supplement3. Press ENTER to display the repeater port settings on that connector.4. Use the arrow keys to highlight the PORT STAT. field of the repeaterport being enabled or disabled.5. Use the SPACE bar to toggle to the appropriate setting (Enable orDisable).6. If setting more than one repeater port, repeat steps 4 and 5 for each oneand then proceed to step 7.7. Use the arrow keys to highlight the SAVE command.8. Press ENTER. The message “SAVED OK” displays and all settingsare saved.3.2.3 Setting Operating Mode On All Repeater PortsThe repeater ports on a connector can be set to the same operating modesimultaneously using the SET ALL PORTS field, as follows:1. Use the arrow keys to highlight the CONNECTOR # field.2. Use the SPACE bar to step to the appropriate connector number.3. Press ENTER to display the repeater port settings on that connector.4. Use the arrow keys to highlight the SET ALL PORTS field.5. Use the SPACE bar to step to the appropriate Operating Mode(Auto-Neg, 10Base-T, or 100Base-TX).6. Press ENTER.7. Enable or disable each repeater port as needed. Refer to Section 3.2.2for instructions.8. Use the arrow keys to highlight the SAVE command.9. Press ENTER. The message “SAVED OK” displays and all repeaterports of the connector are set to the selected operating mode.NOTEIf LockedOnAddr is chosen as the Security State, the individualport must be configured in the Port Level SecurityConfiguration screen. Sections 3.4 provides instructions forconfiguring individual ports.