The WAN Interface Configuration ScreenWPIM-T1/DDS User’s Guide3-7Site #1 is using the full T1, so all the Timeslots must have an Interfaceassignment. Site #2 and Site #3 use only a fraction of the T1, but the totalquantity of Timeslots must match those of Site #1. Unused Timeslotsreceive an Interface number of 000.3.2 THE WAN INTERFACE CONFIGURATION SCREENThe following sections describe the features of the WAN InterfaceConfiguration screen. Access the screen by using the arrow keys tohighlight the WAN INT CONFIG command field at the bottom of theWAN Physical Configuration screen, then press ENTER. The WANInterface Configuration screen shown in Figure 3-4 displays.Figure 3-4 WAN Interface Configuration ScreenNOTEThe Interface numbers of Site #1, Site #2 and Site #3 do nothave to match. Only the quantity and position of Timeslotsmust match (the service provider assigns the Timeslots).WAN INTERFACE CONFIGURATIONRETURNSAVEInterface Number: 000Max Xmit Unit: 0ProtMgr Iface: [0]Active Protocol: FRFR LMI: [ANSI_94]DLCI Address: 0DLCI DCP En:DLCI DCP Stat:Comp Ratio:Circuit State: [Invalid]2750_04 Local Management Flash Image Version: xx.xx.xx001002003004005006007008009010011012013014015CKT# IF# LID STATE018019020021022023024025026027028029030031032CKT# IF# LID STATE016017001 Enet UPPORTS:[1-32 ]002 Enet DOWN