Audit logIntroductionAll changes related to security settings are logged in the Audit log. They can be downloadedand/or cleared.The operations stored in the Audit logIn Océ Express WebTools, open the 'Security' - 'Audit log' tab to download the Audit events logthat contains information on any change made in settings.Collected information on each setting is:1. Username (if available)2. Host (IP address and name) or printer user interface from where the modification was done3. Type of event (create/modify/delete/start/stop/action)4. Object concerned (setting/template name, service name, operation/action)5. New value (if applicable, and not logged for password fields)6. Timestamp in UTC (date&time in ISO-8601 format, yyyy-mm-ddThh:mm:ssZ)7. Event status (success, Failure)User (Key operator, System administrator, Power user) and Service settings:• IPv4network settings (IP address, Subnet mask, DNS, Gateway, DHCP, …)• Network services (enable/disable/settings)• Changes of passwords used to protect security-related settings (Key operator, Systemadministrator, Power user, Service)• Timezone• Remote service online connection (enabled/disabled)• Allow Service Technician to reset passwords (on/off)• Save retrieved job data for service (on/off)• HTTPS settings (change of certificate)• HTTP proxy settings (for remote service)• Force entry of accounting data for print (on/off)• Startup/ shutdown of the audit functionality• Tracking info: when someone logs on to view or to change non-security settings• Changing date and time• Use of save and restore configurationEach log-in operation by the System administrator, the Key operator, and the Power user is alsostored into the audit log.Service settings only:• Retrieval of job data by Service• Resetting of passwords by Service• Remote Service connection (enabled/disabled)• Audit log exportAudit logChapter 7 - Security on Océ ColorWave 810, Océ ColorWave 900 and Océ ColorWave 910 395