COPYRIGHT © 2002 CANON INC. 2000 CANON iR1600/iR2000 REV.1 JAN. 2002 6-25CHAPTER 6 PICKUP/FEDING SYSTEM5.2.2 Removing the Manual feed Pickup Roller1) Remove the durm unit.2) Remove the developing assembly (7.2.1in Chapter5).3) Remove the multifeeder tray.4) Remove the 2 stepped screws [1] usinga screwdriver; then, keeping your handsas shown, detach the pickup guide as-sembly [2] by lifting it upward to thefront.F06-502-035) Remove the manual feed pickup roller[3].When MountingAfter mounting the manual feedpickup roller, rotate the manualfeed pickup roller until it stops,and check to make sure that thecam [4] is as shown.F06-502-04[1][3][4]