TROUBLESHOOTINGError CodesThe Model 225 indicator is equipped with software that indicates when an error in theoperation takes place. The following lists the error codes displayed by the 225 along with their, please refer to this list for the cause.¤ ¤ ¤ ¤d range of the indicator.meaning. Should you encounter an error codeANALOG HIGH¤ ¤ ¤1. The load cell input is above the alloweUCORRECTIVE ACTIONU: Check for impropeoutput of 1 to 40mV.Load cell or circuit failure.r load cell wiring, excessive load, and for2.UCORRECTIVE ACTIONU: Consult your scale service provider.1. The load cell input is below the allowed range of the indNANALOG LOW¤ ¤ ¤ ¤ ¤ ¤ ¤icator.UCORRECTIVE ACTIO U: Check for improper load cell wiring and for output of 1 to 40mV.2. Load cell or circuit failure.UCORRECTIVE ACTIONU: Consult your scale service provider.lus 9UCORRECTIVE ACTIONOVERCAP¤ ¤ ¤ ¤ ¤ ¤ ¤The load on the scale exceeds the scale capacity (105% of capacity if USA=YES or pdivisions if USA=NO). May indicate miscalibration.U: Remove the over capacity load from the scale platform. Consultyour scale service provider regarding recalibration.CHECK MATLIn a Digital Fill Control or Batcher operation configured for decumulative operation(ACCUMLATE=YES) there is not enough material to start the operation.UCORRECTIVE ACTIONU: Determine the reason for the error display and take theappropriate corrective action.CHECK ZEROIn a Digital Fill Control or Batcher operation with DUMP GATE=YES and AUTOTARE=NO the weight is above the zero tolerance value.UCORRECTIVE ACTIONU: Determine the reason for the error display and take theappropriate corrective action.8200-M538-O1 y 225 Installation Page 103