7 x Operation, ParametersDAIKIN EKHHP(3/5)00AA2V3DAIKIN Hot water heat pump008.1423444_05 – 08/2016Installation and operating instructions257.3.4 High OutputIt is heated to the set hot water temperature as quickly as pos-sible using a heat pump and integrated electric Booster Heaters(BSH).The operating mode "High Output" can be activated if larger hotwater draw-off volumes are required for a short period.● Press the key. Icon flashes in the controller display.The output support is automatically deactivated again once thespecified target temperature for hot water is reached.7.4 Setting the timer programmeThe DAIKIN EKHHP can be controlled according to manual set-tings or according to a freely-programmable timer programme.A timer programme is not included at the factory.The user can programme up to 5 switching points for each day tocontrol the hot water generation and the operating mode (normal,low noise).The timer programme is switched on and off using the key.Saved time switching points can be changed or deleted at anytime. To have a better overview, we recommend making a recordof the programmed switching times and keeping this in a safeplace.The user can carry out manual setting changes even if the timerprogramme is switched on. The controller always only works ac-cording to the most recent user parameters set until new param-eters are set. In this way, manually executed settings are can-celled by the timer programme at the next active switch time.The integrated Booster-Heater (BSH) is also controlled fully-au-tomatically by the controller integrated in the DAIKIN EKHHP.The switching limits and switching time periods are defined in theparameter settings. If the Booster-Heater (BSH) is added in, thecontroller dispaly shows the symbol .7.4.1 Display switching times1. Press the key. The current operating mode flashes.2. Use the and keys to select the operating mode to beprogrammed. The selected operating mode flashes.3. Use the key to confirm the selection. The first weekday "MON" is displayed.4. Use the and keys to select the weekday tobe programmed.5. Use the key to confirm the selection. The first switching time programmed for the selectedoperating mode is displayed.6. Use the and keys to move to the otherswitching times for this operating mode. Empty switchingtimes are not displayed.This key moves you back by one step.7.4.2 Programming switching times7. Hold the key pressed for 5 s.8. Use the key to select the switching time number.9. Use the and keys to set the starting time.10. By pressing the key, you can select the type ofswitching for this switching time number.11. Confirm the switching time and switching type using thekey (press briefly).12. Repeat steps 8 to 11 to program the other switching times orto change to the highest switching time of the current day (seestep 6). Then continue with step 13 to completeprogramming.13. Hold the key pressed for 5 s. The switching time set is displayed, saved and all switch-ing times below that are also saved. All switching timesabove the current switching time are deleted. It automatically returns to step 6.7.4.3 Delete switching timeDelete individual switching timesDeleting one or more programmed switching times is carried outat the same time as saving the programmed switching times. Thefollowing table explains the procedure.If the DAIKIN EKHHP is in an "OFF" period, the tariffcontacts HT/NT and SG can no longer be evaluatedand thus have no influence on the operation of theinstallation.Fig. 7-2 Display and programme switching times