Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Figures
- Tables
- Preface
- Revision history
- Chapter 1 Pre-planning tasks
- Before you begin
- VMAX All Flash packaging
- Chapter 2 Delivery and transportation
- Delivery arrangements
- Shipping and storage environmental requirements
- Chapter 3 Specifications
- Radio frequency interference
- Power consumption and heat dissipation
- Adaptive cooling
- Airflow
- Air volume, air quality, and temperature
- Air quality requirements
- Shock and vibration
- Hardware acclimation times
- Optical multimode cables
- Chapter 4 Data Center Safety and Remote Support
- Fire suppressant disclaimer
- Chapter 5 Physical weight and space
- Floor load-bearing capacity
- Physical space and weight
- Chapter 6 Position VMAX 250F Bay
- Bay layout and dimensions
- Tile placement
- Cabinet stabilizing
- Chapter 7 Position VMAX 450F, VMAX 850F, VMAX 950F Bays
- System bay layouts
- Adjacent layouts, VMAX 450F, VMAX 850F, VMAX 950F
- Dispersed layout, VMAX 450F, VMAX 850F, VMAX 950F
- Adjacent and dispersed (mixed) layout
- Dimensions for array layouts
- Caster and leveler dimensions
- Chapter 8 Power cabling, cords and connectors
- Power distribution equipment, VMAX 250F
- Power distribution unit VMAX 450F, VMAX 850F, VMAX 950F
- Wiring configurations, VMAX 250F
- Wiring configurations, VMAX 450F, VMAX 850F, VMAX 950F
- Power interface
- VMAX 250F customer AC power feed cabling
- Best practices: Power configuration guidelines
- Single-phase
- Three-phase (International (Wye))
- Three-phase (North American (Delta))
- Three-phase (Wye, Domestic)
- Chapter 9 EMC racking for VMAX 250F
- Two system configurations
- Chapter 10 Third Party Racking Option for VMAX 250F
- Computer room requirements, VMAX 250F
- PDU requirements for third party racks, VMAX 250F
- Power distribution equipment for third-party rack, VMAX 250F
- Chapter 11 Third Party Racking Option for VMAX 450F, VMAX 850F and VMAX 950F
- Computer room requirements
- Customer rack requirements
- Third party racks with vertical PDUs — RPQ Required
- Requirements for third party racks with vertical PDUs (rear-facing
- Requirements for third party racks with vertical PDUs (inward facing)
- Chassis to chassis grounding
- Chapter 12 Optional kits
- Overhead routing kit
- Dispersion kits, VMAX 950F
- Securing kits
- Appendix A Best Practices for AC Power Connections
- Best practices overview for AC power connections
- Selecting the proper AC power connection procedure
- Procedure A: Working with the customer's electrician onsite
- Procedure A, Task 1: Customer's electrician
- Procedure A, Task 2: EMC Customer Engineer
- Procedure A, Task 2: EMC Customer Engineer (VMAX 250F)
- Procedure A, Task 3: Customer's electrician
- Procedure B: Verify and connect
- Procedure C: Obtain customer verification
- Applying PDU labels, VMAX 250F
- Applying PDU labels, VMAX 450F, VMAX 850F, VMAX 950F
- AC power specifications
|
Two system configurationsTwo VMAX 250F systems can be installed in a rack. Each system can have one or twoV-Bricks. The second system must be installed as a field upgrade option.VMAX 250F systems in a rack must conform to the following requirements:l Lower system: 1U - 20Ul Upper system 21U - 40UThe following diagrams illustrate possible configurations for two VMAX 250F systemsin a rack.EMC rack requirements for customer componentsCustomer components can coexist in an EMC rack with a VMAX 250F system. Thesystem must be properly positioned within the rack in accordance with followingphysical placement rules:l EMC equipment should stack from the bottom while customer equipment stacksfrom the top of the rack.l A system must exist within contiguous space.(Customer equipment must be above a VMAX 250F system and not interwovenwithin the EMC system.)l All customer equipment must be electrically isolated and powered by a second pairof PDP/PDUs. This pair is sold as an optional kit.l EMC racks with two VMAX 250F systems cannot install customer components inthe rack.EMC racking for VMAX 250F88 Site Planning Guide VMAX 250F, VMAX 450F, VMAX 850F, VMAX 950F with HYPERMAX OS