NOTE: The server must be turned off to change the slot state. All servers must be turned off tochange the fabric state. The MAC/WWN addresses must be managed locally (not by an externalconsole) to run this command.Synopsis • racadm setflexaddr -i 0|1• racadm setflexaddr -f 0|1Input • -i — Enables or disables FlexAddress for the specified slot.• -f — Enables or disables FlexAddress for the specified fabric.• = 1–16• = A, B, C, iDRAC– 0 : Disable– 1 : EnableExample • Disable flexaddress for slot 2.racadm setflexaddr -i 2 0• Enable flexaddress for fabric A.racadm setflexaddr -f A 1• Disable flexaddress for fabric B.racadm setflexaddr -f b 0• Disable flexaddress for fabric iDRAC.racadm setflexaddr -f idrac 0setledDescription Sets the state (blinking or not blinking) of the LED on the specified module.To blink or unblink the chassis, I/O modules or the CMC, you must have the Debug Administrator privilege. Toenable the servers to blink or unblink, you must have the Server Administrator or the Debug Administratorprivilege.Synopsis racadm setled -m -l Input • -m — Specifies the module whose LED you want to configure. can be one of the following:– server–, where n=1–16– server–, where n=1–8; x = a, b, c, d (lower case)– switch–, where n=1–6– cmc-active– chassis• -l — Specifies the LED state. The values are:– 0 — No Blinking– 1 — BlinkingExample • racadm setled -m chassis -l 1Sets LED state on Chassis to Blink• racadm setled -m server-1 -1 1LED state was set successfully.67