64 Using the System Setup Program and UEFI Boot ManagerEmbedded Server Management ScreenSerial Port Address(Serial Device 1=COM1,Serial Device2=COM2default)Sets the serial port addresses for the two serial devices.NOTE: Only Serial Device 2 can be used for Serial OverLAN (SOL). To use console redirection by SOL, configurethe same port address for console redirection and theserial device.External Serial Connector Specifies whether Serial Device 1, Serial Device 2, orRemote Access Device has access to the external serialconnector.NOTE: Only Serial Device 2 can be used for Serial OverLAN (SOL). To use console redirection by SOL, configurethe same port address for console redirection and theserial device.Failsafe Baud Rate(115200 default)Displays the failsafe baud rate used for consoleredirection. BIOS attempts to determine the baud rateautomatically. This failsafe baud rate is used only if theattempt fails. This rate should not be adjusted.Remote Terminal Type(VT 100/VT220 default)Sets the remote console terminal type, eitherVT100/VT220 or ANSI.Redirection After Boot(Enabled default)Enables or disables BIOS console redirection when theoperating system is loaded.Option DescriptionFront Panel LCD Options Options are User Defined String, Model Number, orNone.If the LCD Home screen is set to an option other thanthese three choices, the option will be displayed as"Advanced" in the BIOS. In this event, the option cannotbe changed in the BIOS unless it is changed back to UserDefined String, Model Number, or None throughanother LCD configuration utility (such as the iDRACConfiguration Utility or the LCD panel menu).User-Defined LCD String You can enter a name or other identifier for the system, tobe displayed on the LCD module screen.Option Description