202 Management: Firmware DownloadsDownloading Both RAID Controller and NVSRAMFirmwareNOTE: I/O to the array can continue while you are upgrading RAID controller andNVSRAM firmware.NOTE: Dell recommends that the firmware and NVSRAM be upgraded during amaintenance period when the array is not being used for I/O.NOTE: The RAID enclosure must contain at least two disk drives in order to updatethe firmware on the controller.To download RAID controller and NVSRAM firmware in a single operation:1 If you are using the EMW, go to step 9. If you are using the AMW, go tostep 2.2 Perform one of these actions:• Select Advanced Maintenance Download RAID ControllerModule Firmware.• Select the Support tab, and click Download Firmware. In Selectdownload task, select the Download RAID controller modulefirmware and click OK.NOTE: The RAID Controller Module Firmware area and the NVSRAM area listthe current firmware and the current NVSRAM versions respectively.3 To locate the directory in which the file to download resides, click SelectFile next to the Selected RAID controller module firmware file text box.4 In the File Selection area, select the file to download.By default, only the downloadable files that are compatible with thecurrent storage array configuration is displayed.When you select a file in the File Selection area of the dialog, applicableattributes (if any) of the file are displayed in the File Information area.The attributes indicate the version of the file.5 If you want to download an NVSRAM file with the firmware, selectTransfer NVSRAM file with RAID controller module firmware, and clickSelect File next to Selected NVSRAM file.6 To transfer the files to the RAID controller module without activatingthem, click Transfer files but don't activate them (activate later).