v I = Informational suggestion to userv W = Warning. Remedial action is advised. Performance of data may be at risk.v C = Critical immediate remedial action is required.Tape Alert Flag structureBit 7 6 5 4 3 2 1 0Byte0 (MSB) Parameter Code (n)1 (LSB)2 DU(0) (DS(1) TSD(0) ETC(0) TMC(0) Reserved Reserved LP(0)3 Parameter Length (1)4 Value of Flag (Set when bit 0 = 1)Field descriptions:Parameter Code:The Parameter Code is a 2-byte value that uniquely identifies the parameter within the log. Itranges from 1..64DU: Disable Update is set for any parameter that the Host cannot reset.DS: Disable Save. The media changer has no support for SP bit. Set to 1.TSD: Target shall determine save method.ETC: No threshold comparisonTMC: No threshold supportedLP: The List Parameter field is set to zero for parameters that are counters and set to one forparameters that are not counters.Statistics Counter Page (30h)This page consists of the Page Header followed three vendor specific counters. The information in thispage is stored in NV-RAM on power shut-down. This page will not be affected by the LOG SELECTcommand nor by Firmware updates.Bit 7 6 5 4 3 2 1 0Byte0 Reserved Page Code (30h)1 Reserved2 (MSB) Page Length (0048h)3 (LSB)4 - 51 9 Statistics Counter structures (72 bytes)Field descriptions:Page Code:The Page Code echoes the page code that was specific in the Log Sense CDB.Chapter 3. Supported SCSI Commands 3-17