Bit 7 6 5 4 3 2 1 0Byte... Error Event data (n bytes)13 +(n-1)(LSB)(13 +n(MSB)... Error Event description (max. 80 ASCII characters)96 (LSB)Field descriptions:Parameter Code:The Parameter Code is a 2-byte value that uniquely identifies the error event structure the log. Itranges between 1 and 64.DU: Disable Update is set for any parameter that the Host cannot reset.DS: Disable Save. The media changer has no support for SP bit. Set to 1.TSD: Target shall determine save method.ETC: No threshold comparisonTMC: No threshold supportedLP: The List Parameter field is set to zero for parameters that are counters and set to one forparameters that are not counters.Parameter Length:The parameter length field specifies the length of the whole error event structure without the 4byte header.Event Type:This field specifies the event type. Since this page only returns error events it is set to 80h,indicating Hard Error event.Source module ID of Error Event:This field specifies the ID of the source module which generated the error event. See Log Sensepage 07h for detailed information about the possible source module IDs.Time of Event:This field records the time the error event took place.Length of Error Event data:This field specifies the length in number of bytes of the error event data field.Error Event data:This field returns specific information about the error event.Error Event description:This field describes the error event in ASCII text. The returned string is zero terminated. Themaximum string length returned is 80 bytes.3-20 TL2000 and TL4000 SCSI Reference