changed from a LTO full height to half height configuration in order for the libraryto operate properly. If just adding a new drive to the configuration the restorefactory default is not required - only a power cycle of the library.Table 5-3. Factory Default SettingsRestored Item Default Setting* CommentsAutoclean DisabledLogical Libraries 1Active Slots MaximumI/O Slots EnabledEncryption NoneDHCP EnabledIPv4/IPv6 Default Setting IPv4 OnlyBar Code Label Length 8SNMP DisabledEmail Notifications NoneUser Access Restore from Operator Control Panelor Web User InterfaceAdmin secure (default)Library Mode RandomLibrary Name Default (Depends on MAC Address)Logs & Traces ContinuousPath Failover Key No change Key is protectedDrivesPower Power On (All drives)Drive 1 SCSI-ID 4 SCSI DrivesDrive 2 SCSI-ID 5 SCSI DrivesDrive 3 SCSI-ID 6 SCSI DrivesDrive 4 SCSI-ID 8 SCSI DrivesDrive 1 Loop-ID 4 FC Drives Arbitrated LoopDrive 2 Loop-ID 5 FC Drives Arbitrated LoopControl Path Drive Drive 1 onlyPartitions NoneReserved Slots 2U: 24, 4U: 48IPv6 Stateless Autoconfig OffNote: * = all settings at library firmware level 4.xx and greaterIn some cases, (such as Library Mode), the entry of one option precludes any otheroptions from being selected. In such cases, the details of the non-applicable optionsare not shown.Configure: Set Date and TimeUse this menu item to set the current date and time in your library.Chapter 5. Operations 5-25