Note: The small gray markers show where conductive tape should be placedto provide ESD protection.13. Push the black tab (8 in Figure 10-5 on page 10-4) back underneath thelibrary. When inserted properly, only the handle of the tab will be visible.14. Upgrade library firmware and drive firmware to the latest version.Note: Go to http://support.dell.com to download the latest firmware for yourlibrary and tape drive(s).15. Run the Library Verify test. (Operator Control Panel: Service → LibraryVerify). This test requires the use of a scratch (blank) cartridge.v If the test passes:– When prompted by the Operator Control Panel display and the I/OStation opens, remove the cartridge used in the test.– Close the I/O Station by pushing it back into the library.– Press Cancel to exit the Library Verify screen.– Resume normal library operations.v If the test fails, an error code will be displayed. Make note of the error,then refer to the Troubleshooting chapter in this document for additionalinstructions.16. Return the failed drive sled to Dell.Replacing a Power Supply1. Power OFF the library by pressing and holding down the power button for 4seconds.2. Disconnect the power cord from the electrical source, then from the library.2U Library 4U Librarya77ug203Figure 10-8. Diagrams for applying conductive tape for ESD protection to the back of a drive sled installed in a 2U or4U libraryChapter 10. Check, Adjust, Remove, and Replace 10-7