Also see for IDRAC6:
User guide
Table of content
Contents
Table Of Contents
Table Of Contents
Table Of Contents
Table Of Contents
Table Of Contents
Table Of Contents
Table Of Contents
Table Of Contents
Table Of Contents
Table Of Contents
Table Of Contents
Table Of Contents
Table Of Contents
Table Of Contents
Table Of Contents
Table Of Contents
Table Of Contents
Table Of Contents
Table Of Contents
Table Of Contents
Table Of Contents
Table Of Contents
Table Of Contents
Table Of Contents
Table Of Contents
Table Of Contents
iDRAC6 Enterprise Overview
IPv6 Ready Logo Certification
iDRAC6 Enterprise and vFlash Media
Supported Platforms
Supported Operating Systems
Other Documents You May Need
Configuring iDRAC6 Enterprise
Configuration Tasks
Configure iDRAC6 Users
Configure Platform Events
Configure Secure Sockets Layer (SSL)
Configuring Networking Using the CMC Web Interface
Configuring Networking for iDRAC6
Viewing FlexAddress Mezzanine Card Fabric Connections
FlexAddress MAC for iDRAC6
Remote Syslog
Remote File Share
Updating iDRAC6 Firmware
Executing the Firmware Update
Verifying the Digital Signature for Linux DUPs
Using iDRAC6 Web Interface
Updating iDRAC6 Firmware Using RACADM
Using the DOS Update Utility
Clear Your Browser's Cache
Using iDRAC6 Web Interface to Enable Discovery and Monitoring
Using IT Assistant to View iDRAC6 Status and Events
Station
Configuring a Supported Web Browser
Adding iDRAC6 to the List of Trusted Domains
Setting the Locale in Linux
Disabling the Whitelist Feature in Firefox
Installing iDRAC6 Software on the Management Station
Uninstalling RACADM
Installing Telnet or SSH Clients
Configuring the Backspace Key For Telnet Sessions
Installing a TFTP Server
Installing Dell Management Console
Server
Configuring the Managed Server to Capture the Last Crash Screen
Disabling the Windows Automatic Reboot Option
Using the Web Interface
Accessing the Web Interface
Logging Out
Configuring iDRAC6 NIC
Configuring IP Filtering and IP Blocking
Configuring Platform Events
Configuring Platform Event Filters (PEF)
Configuring E-Mail Alerts
Configuring IPMI Over LAN
Adding and Configuring iDRAC6 Users
Securing iDRAC6 Communications Using SSL and Digital Certificates
Secure Sockets Layer (SSL)
Accessing the SSL Main Menu
Generating a New Certificate Signing Request
Uploading a Server Certificate
Viewing a Server Certificate
Configuring and Managing Active Directory Certificates
Configuring Active Directory (Standard Schema and Extended Schema)
Viewing an Active Directory CA Certificate
Configuring iDRAC6 Services
Updating iDRAC6 Firmware Using the CMC
Active Directory
Prerequisites for Enabling Active Directory Authentication for iDRAC6
Extended Schema Active Directory Overview
Overview of iDRAC6 Schema Extensions
Accumulating Privileges Using Extended Schema
Configuring Extended Schema Active Directory to Access iDRAC6
Active Directory Users and Computers Snap-In
Adding iDRAC6 Users and Privileges to Active Directory
Extended Schema Using iDRAC6 Web Interface
Configuring Active Directory With Extended Schema Using RACADM
Overview
Single Domain Versus Multiple Domain Scenarios
Configuring Standard Schema Active Directory to Access iDRAC6
Configuring Active Directory With Standard Schema Using RACADM
Testing Your Configurations
Enabling SSL on a Domain Controller
Certificate
Using Active Directory to Log In to iDRAC6
Using Active Directory Single Sign-On
Logging Into iDRAC6 Using Single Sign-On
Active Directory Certificate Validation
Miscellaneous
Authentication
Logging Into iDRAC6 Using Active Directory Smart Card Authentication
Enabling Kerberos Authentication
Prerequisites for single sign-on and Active Directory Authentication Using Smart Card
Using Smart Card
Configuring Active Directory Users for Smart Card Logon
iDRAC6 Login Scenarios with TFA and SSO
Health of the Managed Server
Integrated Dell Remote Access Controller 6 - Enterprise
WWN/MAC
Batteries
POST
Power Monitoring and Power Management
Power Monitoring
Power Budgeting
Viewing Power Budget
Power Control
Serial Over LAN
Configuring Serial Over LAN in iDRAC6 Web GUI
Using Serial Over LAN (SOL)
Model for the SOL Proxy
Using SOL over PuTTY
Using SOL over OpenSSH with Linux
Opening SOL with SOL proxy
Operating System Configuration
Windows 2003 Enterprise
Using GUI Console Redirection
Supported Screen Resolutions and Refresh Rates
Configuring Console Redirection and Virtual Media in iDRAC6 Web Interface
Opening a Console Redirection Session
Using the Video Viewer
Synchronizing the Mouse Pointers
Frequently Asked Questions
Card for Use With iDRAC6
Removing a vFlash Media Card
Formatting the vFlash Media Card
Viewing the vFlash Key Size
Resetting the vFlash Media Card
Configuring and Using Virtual Media
Windows-Based Management Station
Linux-Based Management Station
Configuring Virtual Media
Running Virtual Media
Disconnecting Virtual Media
Installing Operating Systems Using Virtual Media
Using the RACADM Command Line Interface
RACADM Subcommands
Supported RACADM Interfaces
Using local RACADM Commands
Using the RACADM Utility to Configure iDRAC6
Managing iDRAC6 Users with RACADM
Adding an iDRAC6 User
Removing an iDRAC6 User
Testing iDRAC6 SNMP Trap Alert Feature
Configuring PEF
Configuring PET
Configuring IP Filtering (IP Range)
Configuring IP Filtering
Configuring IP Blocking
Configuring iDRAC6 Telnet and SSH Services Using Local RACADM
Remote and SSH/Telnet RACADM
Remote RACADM Usage
Using an iDRAC6 Configuration File
Configuration File Syntax
Modifying iDRAC6 IP Address in a Configuration File
Loading the Configuration File Into iDRAC6
SM-CLP Command Line Interface
System Management With SM-CLP
SM-CLP Features
Navigating the MAP Address Space
Using the -level Option
Server Power Management
Updating iDRAC6 Firmware Using SM-CLP
Using the WS-MAN Interface
Supported CIM Profiles
Deploying Your Operating System Using iVMCLI
Creating a Bootable Image File
Deploying the Operating System
Line Interface Utility
Installing the iVMCLI Utility
Command Line Options
iVMCLI Operating System Shell Options
Using iDRAC6 Configuration Utility
Starting iDRAC6 Configuration Utility
iDRAC6 LAN
LAN Parameters
Virtual Media Configuration
System Services
Reset to Default
System Event Log Menu
Recovering and Troubleshooting the Managed System
Trouble Indicators
Hardware Trouble Indicators
Problem Solving Tools
Checking the System Event Log (SEL)
Checking the Post Codes
Viewing the Most Recent Boot Sequences
Checking the Server Status Screen for Error Messages
Viewing iDRAC6 Log
Viewing System Information
Identifying the Managed Server in the Chassis
Managing Power on a Remote System
Troubleshooting and Frequently Asked Questions
help
config
getconfig
getssninfo
getsysinfo
getractime
setniccfg
getniccfg
getsvctag
racreset
racresetcfg
getraclog
clrraclog
clrsel
sslcsrgen
sslcertupload
sslcertdownload
sslcertview
testemail
testtrap
vmdisconnect
clearasrscreen
fwupdate
krbkeytabupload
vmkey
coredump
coredumpdelete
ifconfig
netstat
ping6
traceroute
traceroute6
remoteimage
Database Group and Object Definitions
idRacInfo
idRacBuildInfo (Read Only)
cfgOobSnmp
cfgLanNetworking
cfgDNSDomainName (Read/Write)
cfgDNSRegisterRac (Read/Write)
cfgDNSServer2 (Read/Write)
cfgNicIpAddress (Read/Write)
cfgNicUseDhcp (Read/Write)
cfgNicVLanEnable (Read Only)
cfgIPv6URL
cfgIPv6Address1 (Read/Write)
cfgIPv6AutoConfig (Read/Write)
cfgIPv6DNSServer1 (Read/Write)
cfgIPv6DNSServer2 (Read/Write)
cfgIPv6Addr3PrefixLength (Read Only)
cfgIPv6Addr4Length (Read Only)
cfgIPv6Addr6PrefixLength (Read Only)
cfgIPv6Addr7Length (Read Only)
cfgIPv6Addr9PrefixLength (Read Only)
cfgIPv6Addr10Length (Read Only)
cfgIPv6Addr12PrefixLength (Read Only)
cfgIPv6Addr13Length (Read Only)
cfgIPv6Addr15PrefixLength (Read Only)
cfgUserAdminIndex (Read Only)
cfgUserAdminUserName (Read/Write)
cfgUserAdminEnable (Read/Write)
cfgEmailAlertEnable (Read/Write)
cfgSessionManagement
cfgSsnMgtSshIdleTimeout (Read/Write)
cfgSerial
cfgSerialTelnetEnable (Read/Write)
cfgRhostsFwUpdateIpAddr (Read/Write)
cfgRhostsSyslogEnable (Read/Write)
cfgRhostsSyslogServer2 (Read/Write)
cfgUserDomainName (Read/Write)
cfgServerPowerCapWatts (Read Only)
cfgServerPowerCapPercent (Read Only)
cfgRacTuneHttpsPort (Read/Write)
cfgRacTuneIpRangeMask
cfgRacTuneIpBlkFailWindow
cfgRacTuneConRedirEnable (Read/Write)
cfgRacTuneConRedirPort (Read/Write)
cfgRacTuneWebserverEnable (Read/Write)
cfgRacTuneTimezoneOffset (Read/Write)
ifcRacManagedNodeOs
cfgRacSecurity
cfgSecCsrLocalityName (Read/Write)
cfgSecCsrEmailAddr (Read/Write)
cfgVirMediaBootOnce (Read/Write)
cfgVirtualFloppyEmulation (Read/Write)
cfgIpmiLanPrivLimit (Read/Write)
cfgIpmiPetCommunityName (Read/Write)
cfgIpmiPetIPv6AlertDestIpAddr
cfgIpmiPefIndex (Read/Write)
cfgIpmiPefEnable (Read/Write)
cfgIpmiPetAlertEnable (Read/Write)
cfgSmartCardCRLEnable (Read/Write)
cfgADRacName (Read/Write)
cfgADDomainController1 (Read/Write)
cfgADDomainController3 (Read/Write)
cfgADGlobalCatalog3 (Read/Write)
cfgStandardSchema
cfgSSADRoleGroupPrivilege (Read/Write)
cfgIpmiSol
cfgIpmiSolSendThreshold (Read/Write)
Glossary
Index
Integrated Dell
™
Remote
Access Controller 6 (iDRAC6)
Enterprise for Blade Servers
Version 2.1
User Guide
Next
/ 472
Zoom view
Related manuals for Dell IDRAC6
Dell iDRAC7 User Manual
Dell Remote Access Controller 4 Firmware Version 1.30 User Manual