278 Using iDRAC6 Enterprise SM-CLP Command Line Interface• Display system propertiesServer Power ManagementTable 16-3 provides examples of using SM-CLP to perform powermanagement operations on a managed server.Enter "smclp" to start the SM-CLP console.SEL ManagementTable 16-4 provides examples of using the SM-CLP to perform SEL-relatedoperations on the managed system.MAP Target NavigationTable 16-5 provides examples of using the cd verb to navigate the MAP. In allexamples, the initial default target is assumed to be /.Table 16-3. Server Power Management OperationsOperation SyntaxLogging in toiDRAC6 using theSSH interface>ssh 192.168.0.120>login: root>password:Enter "smclp" to start the SM–CLP console.Power down theserver->stop /admin1/system1system1 successfully stoppedPower up the serverfrom a powered-offstate->start /admin1/system1system1 successfully startedReboot the server ->reset /admin1/system1RESET successful for system1