848 OperatingMounting and Operating Instructions CEAG Central Battery System ZB-S 40071860179 (L) November 2018 www.ceag.de Menu 3.9:Select the system or fault messages whichactivate the buzzer in the switch cabinet.A standard setting according to DIN VDE(see Appendix B) can be selected usingthe “Load defaults” option at the end ofthis menu. Highlight the events with Select buzzer “On” () or buzzer“Off” (no ) with keys Finish and return to Menu 3 withote:N The buzzer’s maintained signaltone (after the onset of an eventspecified here) can be silenced bypressing any key.ote:N “Brightness (on)” is the display setting when the display is active (press anykey to activate). If no key is pressed within 180 seconds, the controller switch-es the display to passive (dimmed backlighting) “Brightness (off)”.The above settings may make the display unreadable (e.g. depending on theambient lighting).(The active display setting can be changed at any time from the main screenby pressing and a key (for contrast) or (for brightness) of the active LCDdisplay.)Setting contrast and brightness (back-lighting) for the LCD display of the CUCG-S control module. Line selection (2 to 4) with Set the values (0 to 100%) with keys Finish and return to Menu 3 withMenu 3.10:Manual resetSelective EmgcyOper.Relay setupBuzzer setupetc....Selective EmgcyOper.Relay setupBuzzer setupDisplay setupetc....Display settingContrast 50%Brightness on:100%Brightness off: 10%Buzzer assignmentMains operationMains failure Mains failure UV Charge faultCircuit faultLuminaire faultSum failureDeep discharge protectionISO failureFunction testBattery duration testDB-FÜBGerätestörungLoad defaultsOverview:Main menuTest & status menuBlock & reset alarmsBasic settingsDLS/TLS SetupCircuit setupLuminaire setupLogbooksetupSend ServicePinMsgMenu 3LanguageDate & timeFunctiontestDurationtestDelay time mainsreturnManual resetSelective EmgcyOper.Relay setupBuzzer setupDisplay setupCharger setupPrinter setupRelay module setupWebserver setupTimer setupSubstation setupConnection to BMSFunction keysOptional inputsSerialnumber & typePassword protectionDaylight saving timeService info Selection ofmenu optionswith thekeys :confirm selec-tion -cel and returnto the previousmenu (anychanges en-tered are saved) : canceland return tothe previousmenu (anychanges en-tered are notsaved) flashing inputpromptEntries about the switch cabinet equip-ment Select line 2, 3 and 4 with Change the settings with – Line 2: Toggle between“installed” / “not installed”(charging module LT.1 2,5 A or BCM)– Line 3: Number of boosters = 1 ... 10(charge booster 2,5 A)– Line 4: Battery capacity in Ah can beselected between 5 and 999short key press in increments of 1;long key press in increments of 10. Finish and return to Menu 3 with Menu 3.11:Relay setupBuzzer setupDisplay setupCharger setupetc....Important NOTEThese details must be entered exactly or the emergencylighting system controller may fail.Caution: The specification for the number of chargingboosters only applies to 2.5 A charging boosters. If aBCM is mounted, only specification of the number of 2.5A charging boosters is permitted. If no 2.5 A chargingboosters are installed, the specification for „number ofboosters“ must be „0“.Exception: If a CM 3.4 A charging module is installed asa replacement for a 2.5 A charging booster then this mustalso be counted. Observe here that the address of the CM3.4 A charging module is set to „00“.Charger setupinstalledNumber of boosters 4Batt.capacity 80Ah