908 OperatingMounting and Operating Instructions CEAG Central Battery System ZB-S 40071860179 (L) November 2018 www.ceag.deOverview:Main menuTest & status menuBlock & reset alarmsBasic settingsDLS/TLS SetupCircuit setupLuminaire setupLogbooksetupSend ServicePinMsgMenu 5Deactivate moduleSearch ext. modulesText assignmentMonitoring modeDLS/TLS-AssignmentGet new rated value Selection ofmenu optionswith the keys :confirm selec-tion -cel and returnto the previousmenu (anychanges en-tered are saved) : canceland return tothe previousmenu (anychanges en-tered are notsaved) flashing inputprompt Select line 2 or 4 or the input fields inline 2 with Successive selection of subrack/SKUand circuit with Changing the circuit name:– Select line 4 with – Select the input point with – All the possible alphanumericcharacters are displayed cycli-cally with the cursor keys .– Once a name has been fullyentered, confirm the entry with. The remaining charactersafter the current cursor positionare cleared. Finish and return to Menu 5 withote:N This menu can be used to assign/edit circuit names without affect-ing the configuration.The procedure is necessary, forexample when the system is firstcommissioned or after adding SKUmodules.Circuit names are stored on thememory card and displayed inthe LC display menus as opera-tor help. Text assignments cannotbe made with the CU CG-S if amemory card is not inserted!Otherwise, refer to menuoption 4.2Deactivate moduleSearch ext. modulesText assignmentMonitoring modeDLS/TLS-AssignmentGet new rated valueMenu 5.3: Text assignmentsSKU1/8 circuit:2Type: SKU CG-S 2x3Circuit nameMenu 5.4: Select line 1, 2, 3 or the input fields inline 1 with Successive selection of SKU/outputand (final) circuit with Line 4 shows the circuit name (seemenu 5.2) Select the monitoring mode with keys Finish and return to Menu 5 withThe “CG monitoring” option requires CG-S ballasts/modules and therefore addressableluminaires from the CEAG range.For other luminaires, a function test with the “Current value monitoring” option can becarried out on the basis of the current flow in an entire luminaire circuit (refer to thesettings in “5.5 Learn current values”).When “Current value monitoring” is selected, line 3 prompts entry of the maximumdeviation (1 ... 20%) from the reference value determined in “5.5 Learn current values”at which there is still no fault message in a function test.So that the failure of the weak-est luminaire in a final circuit can be detected, select:Pminmax. dev. < ––––– x 100(Pmin = Mains connected load of the smallest luminaire)Pges (Pges = Mains connected load of all installed luminaires)Using a SWR150-module differing to this the current value monitoring has to be set tominimum 15% - acc. to number of type of luminaire and luminous flux.ote:N The above display shows an exam-ple of the selection of “Currentvalue monitoring” for circuit 2,SKU No. 8 on subrack 1.The following modes can be selected inline 2:– CG monitoring– Current value monitoring– Reserve circuitDeactivate moduleSearch ext. modulesText assignmentMonitoring modeDLS/TLS-AssignmentGet new rated valueSKU1/8 circuit:2Current value monitoringmax. deviation20% Circuit name